| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Price : | $500.00/square meters 50-499 square meters |
| Supply Ability : | ≥1 set |
| Model Number : | Customized |
| Delivery Time : | 30 days |
| Payment Terms : | L/C,T/T |
| Certification : | CE、ISO |
| Brand Name : | SHP |

| Application | Pharmaceutical | Lab | Electronics |
| Cleanliness | China class 100 to 100000 | ISO 5 to 8 | EU B to D |
| Scope | Structure part; Partition and ceiling panel; door and window,epoxy. | HVAC part; AHU and chiller; Ducting and piping. | Electrical part; Lamp,switch and socket; Distribution cabinet. |
| Service | Design and production | Construction and test | Validation and training |
| Wall/ceiling panel | Machine-made or Hand-made sandwich board |
| Clean room equipment | Air shower,FFU,Pass box,Laminar flow cabinet,hepa box |
| Cleanliness | Class 100-100000 |
| Purification system | HVAC, or AC conditioner+FFU |
| Floor | PVC anti-static floor or epoxy-based coating |
| Other addessores | stalinite window,LED panel light,Door,Hand wash sink,storage/shoe cabinet etc |
| Service | Design,manufacturing,construction |
1. Air Filtration
Without it: Every cubic meter of indoor air carries millions of submicron particles — invisible dust, skin flakes, soot, fiber fragments — any one of which can short a circuit, clog a nozzle, or contaminate a sterile fill. With it: Multi-stage HEPA/ULPA filtration scrubs the air to fewer than 3,520 particles ≥0.5μm per cubic meter at ISO Class 5, removing 99.997% of particulate threats before they reach the product.
2. Airflow Design
Without it: Particles hover and settle. A dead zone above the workbench becomes a dust reservoir. Contaminants generated by the operator or tool recirculate endlessly. With it: Laminar flow pushes a uniform column of clean air downward at 0.45 m/s, sweeping every particle into the return plenum before it can land. Turbulent dilution in lower-grade zones drives 20–60 air changes per hour to flush the space continuously.
3. Temperature & Humidity Control
Without it: A 2°C drift during photolithography shifts critical dimensions. A humidity spike causes hygroscopic powders to cake. Condensation forms on chilled surfaces, breeding microbes. With it: HVAC loops hold temperature to ±0.5°C and humidity to ±3% RH around the clock, neutralizing outdoor weather, equipment heat loads, and occupancy effects.
4. Pressure Cascading
Without it: Open a door, and unfiltered corridor air floods into the clean zone. Particles migrate freely across the facility. One breach in one room compromises the entire suite. With it: Positive pressure differentials of 5–15 Pa between zones force air to flow only one way — outward from clean to less clean. Even during door operations, dynamic VAV compensation restores the gradient in seconds.
5. Sealed Envelope
Without it: Gaps between wall panels collect dust that no filter can reach. Sharp corners trap debris. Ceiling penetrations leak unfiltered plenum air into the workspace. With it: Factory-laminated panels with flush, silicone-sealed joints. Rounded coves at every wall-to-floor transition. A 100% airtight shell that leaves no surface for dirt to grip.
6. ESD Protection
Without it: A technician walks across the floor, builds a 5,000-volt charge, and touches a fixture — the micro-discharge fries a batch of wafers worth tens of thousands of dollars. With it: Conductive flooring (10⁴–10⁹ Ω surface resistance), grounding straps, and humidity held above 35% RH drain static continuously. Charges can't build, so arcs can't happen.
7. Entry Gowning & Air Shower
Without it: An operator in street clothes carries millions of skin particles, fibers, and bacteria through the door. Within minutes, the cleanroom is as dirty as the hallway outside. With it: A staged protocol — coverall, hood, boots, gloves — followed by a 25 m/s air shower for 15–30 seconds, reduces the particle burden per person by over 90% before entry.
8. Environmental Monitoring
Without it: A filter develops a pinhole leak. A pressure differential collapses. Temperature overshoots by 3°C. Nobody knows until product fails downstream — and the root cause is unprovable because no data exists. With it: Real-time particle counters, pressure sensors, and T/RH probes stream to a BMS/EMS historian, flagging every deviation instantly and building an audit-ready record.
9. Energy Recovery
Without it: The HVAC system runs at full power 24/7, consuming 50–70% of total facility energy, driving operating costs into unsustainable territory. With it: Variable-speed fans throttle down during idle periods. Enthalpy wheels reclaim 60–80% of exhaust energy. The system delivers cleanliness at the lowest possible wattage.
10. Validation
Without it: Someone says "trust us, it's clean" — and the auditor disagrees, halting production, triggering a recall, or refusing market authorization. With it: IQ/OQ/PQ testing proves filter integrity, airflow uniformity, recovery time, and temperature mapping with documented, reproducible data. Certification is a file you can hand to any regulator with confidence.
The Bottom Line
A cleanroom is not a room that happens to be clean. It is an engineered system where ten interdependent functions work together in real time. Remove any one, and the whole chain fails. Keep all ten in spec, and your product never meets a particle it shouldn't.






|